  "ocid": "ocds-b5fd17-fe749460-4f19-4c82-9f2c-80687e2d67fb",
  "slug": "mobile-electroencephalography-eeg-devices-fe749460-4f19-4c82-9f2c-80687e2d67fb",
  "rules": "Earlier rules (before the Procurement Act 2023)",
  "vat_stated": false,
  "title": "Mobile Electroencephalography (EEG) Devices",
  "display_title": "Mobile Electroencephalography (EEG) Devices",
  "url": "https://opencontracts.uk/contract/mobile-electroencephalography-eeg-devices-fe749460-4f19-4c82-9f2c-80687e2d67fb",
  "json_url": "https://opencontracts.uk/contract/mobile-electroencephalography-eeg-devices-fe749460-4f19-4c82-9f2c-80687e2d67fb.json",
  "buyer": {
    "name": "Future Cities Catapult Ltd",
    "display_name": "Future Cities Catapult Ltd",
    "slug": "future-cities-catapult-ltd",
    "url": "https://opencontracts.uk/buyer/future-cities-catapult-ltd",
    "json_url": "https://opencontracts.uk/buyer/future-cities-catapult-ltd.json"
  },
  "status": "active",
  "open_for_tenders": false,
  "stage": "Tender notice",
  "method": "Other - ",
  "category": "goods",
  "cpv_code": "31000000",
  "cpv_description": "Electrical machinery, apparatus, equipment and consumables; lighting",
  "description": "The study of neuroscience in cities has lacked advancement mainly due to technology; we have not had the ability to take equipment outside of the lab to test neuroscience in the \"wild\" resulting in neuroscientists not being able to conduct studies with people in real life environments. Testing neuroscience in the context of the  built environment has, as a result, been limited.  Mobile Electroencephalography (EEG) would open the opportunity for the Catapult to understand the effect of cities on neurology as part of one of our urban Mobility and Healthy Cities agendas. EEG measures brain activity from small recording electrodes by means of specially designed electrode caps.\r\nThe Catapult wishes to purchase two mobile EEG devices, accessories and supporting services for the purpose of advancing its understanding of the the objectives set out above.\r\nThe Catapult requires the mobile EEG devices with the following functionality:\r\n•\tMust be battery operated (at least 4 hours operation) such that it allows for mobile use. \r\n•\tThe devices are to have 128 EEG channels (24 bipolar channels) and have upgradability to 256 EEG channels. \r\n•\tThe devices are to allow the users the high-density EEG stations to be split into separate (mobile) 64-channel EEG systems.\r\n•\tThe devices should allow studies such as:\r\no\tSteady State Visually Evoked Potentials (SSVEP);\r\no\tAn evoked potential (AEP);\r\no\tMismatch Negativity (MMN);\r\no\tP300 (P3) wave; and \r\no\tN2(pc).\r\n•\tThe use of the devices shall permit accuracy in adverse environments.\r\n•\tDevices must be compact and light weight to allow for quick set up to support mobile use.\r\n•\tSystem must have high temporal resolution data through high sampling rate of up to 16 kHz which users may select.\r\n•\tSystem must be highly configurable (including configurable workflows) to allow for studies to be conducted in a diverse range of parametres.\r\n•\tResolution to at least 24 bits.\r\n•\tUSB 2.0 compatible.\r\n•\tElectrode cables do not interfere with EEG recording and not impacted when impedances are high.\r\n•\tSignals shielded from environmental noise.\r\nThe system to be purchased is to include:\r\n•\tTwo systems as above and amplifiers.\r\n•\tBreathing sensor.\r\n•\tTemperature sensor.\r\n•\tGSR sensor.\r\n•\tAccelerometer and 2 bipolar electrodes.  \r\n•\t8 x 128 EEG caps.\r\n•\t1 x 256 EEG cap.\r\n•\tBackpack to allow for cooling and portability of both systems.\r\n•\tDesktop PC, tablet and recording software.\r\n•\tAll equipment to support use as described above including accessories and supporting equipment.\r\n•\tSet up, installation and training.\r\n•\t12 month warranty and two years support service.\r\nThe successful supplier will have experience in the following areas:\r\n•\tManufacturer of mobile EEG systems that support the requirements demonstrated in the ITT;\r\n•\tProvider of support, installation and training of mobile EEG systems;\r\n•\tExperienced with regards to providing expertise in the support of projects of the type descibred that will be utilising the above systems.\r\n\r\nAdditional information: \r\nTo express interest in the requirement and download the ITT please visit www.fccprocurement.org.uk. New suppliers will be required to register. The reference for this opportunity is DN279161",
  "currency": "GBP",
  "estimated_value": "150000.00",
  "estimated_value_gross": null,
  "awarded_value": null,
  "awarded_currency": null,
  "awarded_is_gross": false,
  "is_framework": false,
  "tender_deadline": "2017-06-16T22:59:59+00:00",
  "first_published": "2017-06-02T14:02:36+00:00",
  "last_updated": "2017-06-02T14:02:36+00:00",
  "lots": [],
  "awards": [],
  "contracts": [],
  "notices": [
    {
      "notice_id": "69fe07ac-a6df-4c67-ba81-b2bfb85643c4-151598",
      "label": "Tender notice",
      "date": "2017-06-02T14:02:36+00:00",
      "url": "https://www.contractsfinder.service.gov.uk/Notice/69fe07ac-a6df-4c67-ba81-b2bfb85643c4",
      "source": "contracts_finder",
      "source_url": "https://www.contractsfinder.service.gov.uk/Notice/69fe07ac-a6df-4c67-ba81-b2bfb85643c4",
      "retrieved_at": "2026-11-19T19:59:11.360154+00:00"
    }
  ],
  "licence": "Open Government Licence v3.0",
  "licence_url": "https://www.nationalarchives.gov.uk/doc/open-government-licence/version/3/",
  "attribution": "Contains public sector information licensed under the Open Government Licence v3.0. Source: Find a Tender and Contracts Finder, Cabinet Office.",
  "source": "contracts_finder",
  "source_url": "https://www.contractsfinder.service.gov.uk/Notice/69fe07ac-a6df-4c67-ba81-b2bfb85643c4",
  "retrieved_at": "2026-11-19T19:59:11.360154+00:00",
  "provenance": {
    "source": "contracts_finder",
    "source_url": "https://www.contractsfinder.service.gov.uk/Notice/69fe07ac-a6df-4c67-ba81-b2bfb85643c4",
    "retrieved_at": "2026-11-19T19:59:11.360154+00:00"
  }
}