# Harbour and Emergency Genset

Astilleros Gondan Sa · Active · Tender notice

- Buyer: Astilleros Gondan Sa
- Estimated value: £110,000 (VAT not stated)
- Procedure: Competitive quotation (below threshold)
- Category: Goods
- CPV code: 71000000 Architectural, construction, engineering and inspection services
- First published: 2 June 2023
- Last updated: 2 June 2023
- Rules: before the Procurement Act 2023 (published on Contracts Finder)

## Description

Harbour and Emergency Diesel Generator Set 
One (1) pc combined generator shall be provided, running on MGO only. 
The Engine shall meet IMO TIER III requirements for emissions. 
The generator shall supply the entire Vessel with power in emergency operation. 
The generator shall be designed for standard requirements for an emergency generator. 
The generator shall be designed for powering the vessel and/or the hybrid power bank batteries in 
Harbour Alternator mode.  
When in Harbour Alternator Mode, the engine shall have additional engine shut down in way of 
High Jacket water temperature. 
There shall be clear indication in the emergency generator room and on the ICAM on which mode 
is selected.  

The diesel engine shall be 4-stroke, turbocharged and inter-cooled with direct injection of liquid 
fuel and electronic regulator. The rating shall be for continuous operation, fulfilling the e-load 
calculation. The diesel engine shall be fitted with electrical/water standstill heating. 
The diesel engine shall be with 24 VDC electric starter and a hydraulic starter for emergency start. 
The generator shall be for marine use, brushless type generators with interference VDE 0875, class 
N, or equivalent standards and the following particulars: 

 Voltage 3 Phase, 415 V, 50 Hz 
Power factor Minimum 0.8 
Speed TBC 
Enclosure IP44, air cooled 
Engine cooling Fresh water (Radiator with fan ventilation) 
Alternator cooling Air cooled for marine operations 
Insulation Class H (NEMA classification) or equivalent 
Temperature rise Class F (NEMA classification) or equivalent 
Thermal sensor One in each stator winding plus spare in each winding 
Standstill heating Electrical/Water 

 

The generator shall be equipped with: 
Automatic Voltage Regulator, fuel oil tank with alarm, anti-condensation heater, and sensors for 
vibration analysis monitoring that shall be integrated into the vessel's Condition Monitoring 
system.  
Local sensors: Lube oil pressure and temperature, fuel oil pressure, cooling water pressure and 
temperature, battery status, and header tank level.