Fire Safety Consultations - New Homes
Bromford Flagship Livewest Limited Complete Contract award
- Buyer
- Bromford Flagship Livewest Limited
- Estimated value
- £600,000 as published; Contracts Finder does not say whether VAT is included
- Awarded value
- £600,000 as published, VAT not stated
- Procedure
- Call-off from a framework agreement
- Category
- Services
- CPV code
75251110Fire-prevention services- First published
- 18 Apr 2024
- Last updated
- 18 Apr 2024
- Rules
- Before the Procurement Act 2023: the Public Contracts Regulations 2015 and earlier rules, or below their thresholds
Description
This appointment is to provide fire assessments and consultation services to Bromford. To include but not limited to:
• To read and comprehend any fire strategy documents and plan drawings that have been produce for, and on behalf, of the developer.
• Prior to submission to the relevant building control authority make comments on the fire strategy in line with best practice and report these comments to the client.
• To ensure the fire strategy document is compliant with the building design guidance being adopted for construction e.g. Approved Document B, BS 9991, or BS 9999.
• To ensure that during the phases of building that you are influencing the Contractor/Developer to ensure all appropriate industry standard applications, processes and best practice are adhered to, especially-
o fire ratings for compartmentation.
o fire ratings for compartmentation penetrations.
o fire ratings for installation of fire doors, shutters, dampers and smoke control installations.
o Fire rating and installation of any cavity barriers.
• To be able to determine with BHA/BDL and the Contractor/Developer the suitability of any proposed-
o fire detection & alarm system,
o smoke control system,
o emergency lighting system,
o automatic water suppression system,
o lightning protection system,
o external wall façade system,
o dry rising fire main installation.
• To ensure that suitable access arrangements by way of inspection hatches are provided to allow for ongoing testing, servicing and maintenance of any building system.
• To ensure that suitable photographic records are made of the phases of development including all fire stopping measures which become unseen on completion of works and provided to the client prior to the Practical Completion as defined under the building Contract.
• To check on the competency of installers carrying out specialised works.
• To refer to a suitable expert in the event of any aspect of work falling outside of the consultant's area of competence.
• To liaise with Construction Managers, Project Managers and the Employers Agents to ensure that any identified shortcomings in works are made good to industry best practice. Any defective work should in respect of Fire Safety and adherence to plans ought to be reported to the Employers Agent with photographic evidence and suggestions for remediation copying in the CQM, and Project Manager as well as the wider Project Team of the Developer/Contractor.
• To liaise with Bromford's Fire Safety Team of Fire Risk & Compliance Assessors at suitable times to enable a fire risk assessment to be carried out at, or near to, occupation of the building.
• To inform Bromford of any changes of legislation that may impact the fire risk assessment outcome before completion of the building.
Awards
| Supplier | Value | Date | Status |
|---|---|---|---|
| Firntec Ltd | £600,000 | 18 Apr 2024 | Active |
Notices
- 18 Apr 2024 Contract award
Contracts Finder holds the official notices, with their documents and contact details.