{
  "ocid": "ocds-h6vhtk-05fed3",
  "slug": "control-room-consoles-05fed3",
  "rules": "Procurement Act 2023",
  "vat_stated": true,
  "title": "Control Room Consoles",
  "display_title": "Control Room Consoles",
  "url": "https://opencontracts.uk/contract/control-room-consoles-05fed3",
  "json_url": "https://opencontracts.uk/contract/control-room-consoles-05fed3.json",
  "buyer": {
    "name": "North West Ambulance Service NHS Trust",
    "display_name": "North West Ambulance Service NHS Trust",
    "slug": "north-west-ambulance-service-nhs-trust",
    "url": "https://opencontracts.uk/buyer/north-west-ambulance-service-nhs-trust",
    "json_url": "https://opencontracts.uk/buyer/north-west-ambulance-service-nhs-trust.json"
  },
  "status": "planning",
  "open_for_tenders": false,
  "stage": "Preliminary market engagement notice",
  "method": null,
  "category": "goods",
  "cpv_code": "39121000",
  "cpv_description": "Desks and tables",
  "description": "This pre market engagement notice has been issued to engage with suppliers of control room centre consoles (desking solutions). \nControl rooms are at the heart of operations for the Ambulance Services.  These environments demand high performance, 24/7 concentration and absolute reliability \nFurniture used in these spaces plays a crucial role in supporting operational comfort, focus and health\nPlanning a control room project isn't just about choosing furniture and placing screens, it is about creating a purpose-built environment that supports your team, meets industry standards and stays adaptable for the future\nOperators spend long hours in the control room, especially in mission-critical environments.  That's why ergonomic furniture is essential.  Adjustable Consoles, comfortable seating and smart positioning of monitors all help reduce fatigue and boost concentration. \nControl room furniture is not like standard office furniture.  It needs to be strong, adaptable and fit for purpose, especially in environments where downtime isn't an option.\nNWAS Recommended Desk Specification for Control Room Consoles:\n•\tConsoles / pods ergonomics and rise and fall Consoles should support the Trust responsibilities under the equalities act allowing them to meet the needs of staff fully \n•\t50% of desks as a minimum should be rise and fall\n•\tConsoles should provide design to negate tangled wires, clutter. They should offer protective cable entry points which are hidden behind panels providing protection and access can be restricted to specialist IT colleagues as and when needed \n•\tScreens should be positioned on dynamic arms and a rail which ensure no wobble, no distractions and the ability to quickly reconfigure layouts for shift work or multi-user setups. \n•\tPods should provide In-console power\n•\tTermination boards within the end frame allowing supply power and data modules to be mounted behind a lift-off cover.\n•\tDesktop power modules with limited amps can provide users the opportunity to charge their personal devices (i.e., mobile phones) without having to crawl under the desk and plug into the specific power for specialist equipment\n•\tCorrect arms positions the CRS screen for dispatcher at optimum positioning for operational use \n•\tRunning bar at back also has specific bracket for fixed mobiles to be positioned appropriately on dispatch consoles / pods. \n•\tEquipment and cabling is contained within special housing, reducing clutter and improving the cosmetic set up of the room. \n•\tA minimum desk standard of a minimum of 1600mm width and depth 1000 (to allow for future proofing) call handling and clinical and multi seat functionality.  \n•\tA minimum desk size of 1800 mm width and depth 1000mm will be required for dispatch and ROC \n•\tConsoles / Pods should not be white (to avoid reflection issues with lighting) Polyray laminate finish (colour options to be available) \n•\tDesk / consoles must prioritise operator comfort and productivity through features such as sit - stand functionality and optimised screen placement, for ergonomic excellence.   A mix of sit-stand Consoles / pods as well as static height (minimum of 50%) - these should facilitate no impact to cabling of equipment when rising and ensure this is contained to avoid 'tangling'\n•\tConsoles must be built for durability and accessibility and withstand the rigors of 24/7 operations; they should comply with Health and Safety and Visual Display regulations. \n•\tConsoles should include features such as front and rear access for maintenance and optional pod separation for data and power management. \n•\tConsole arms should provide effortless adjustment and optimal screen positioning. \n•\tSide panels, modesty panels should be provided on consoles as well as privacy panels (which can also act as acoustic softening) \n•\tFloor grommets should be provided for cabling to desk (these should be in an ordered consistent position at each desk - to be determined by IT on desk confirmation) Consoles should provide separate 'fused' power sockets on desk for employee usage (double socket and USB/C)\n•\tEach desk must be UPS backed and generator backed\n•\tDynamic monitor support system facilitating dynamic arm allowing rotate and adjustment of monitors up to 10kg with no tools \n•\tClean cable management, desk should provide functionalities for all cables to be neatly managed, flexible cable anaconda should be provided to keep leads in check at any desk height.\n•\tEvery cable tucked away out of sight, but always reachable when needed. \n•\tFabric screen should be provided in for of a partition which grants privacy and reduces background noise.\n•\tPod should be compliant with ergonomic standards and allows the maximising of space for the user all whilst providing.\no\tAmple provision for power and data modules. (minimum 8 power and 6 data) \no\tKeep cool, both you and your equipment are kept comfortable.\no\tAccommodate up to two workstation PCs.\no\tModesty panels for every posture\no\tAvailable as a height adjustable and standard \no\tLowest seated worktop height is 650mm \no\t1200mm for standing\no\tRaise to 1310mm for IT access\no\tAdequate space for feet\no\tErgonomic standard EN527 \n•\tPods should provide In-console power\n•\tTermination boards within the end frame allowing supply power and data modules to be mounted behind a lift-off cover.",
  "currency": null,
  "estimated_value": null,
  "estimated_value_gross": null,
  "awarded_value": null,
  "awarded_currency": null,
  "awarded_is_gross": false,
  "is_framework": false,
  "tender_deadline": null,
  "first_published": "2026-01-02T15:46:19+00:00",
  "last_updated": "2026-01-02T15:46:19+00:00",
  "lots": [
    {
      "id": "1",
      "title": null,
      "status": "planning",
      "value": null,
      "value_gross": null,
      "currency": null,
      "source": "find_a_tender",
      "source_url": "https://www.find-tender.service.gov.uk/Notice/000075-2026",
      "retrieved_at": "2026-11-18T17:29:12.024213+00:00"
    }
  ],
  "awards": [],
  "contracts": [],
  "notices": [
    {
      "notice_id": "000075-2026",
      "label": "Preliminary market engagement notice",
      "date": "2026-01-02T15:46:19+00:00",
      "url": "https://www.find-tender.service.gov.uk/Notice/000075-2026",
      "source": "find_a_tender",
      "source_url": "https://www.find-tender.service.gov.uk/Notice/000075-2026",
      "retrieved_at": "2026-11-18T17:29:12.024213+00:00"
    }
  ],
  "licence": "Open Government Licence v3.0",
  "licence_url": "https://www.nationalarchives.gov.uk/doc/open-government-licence/version/3/",
  "attribution": "Contains public sector information licensed under the Open Government Licence v3.0. Source: Find a Tender and Contracts Finder, Cabinet Office.",
  "source": "find_a_tender",
  "source_url": "https://www.find-tender.service.gov.uk/Notice/000075-2026",
  "retrieved_at": "2026-11-18T17:29:12.024213+00:00",
  "provenance": {
    "source": "find_a_tender",
    "source_url": "https://www.find-tender.service.gov.uk/Notice/000075-2026",
    "retrieved_at": "2026-11-18T17:29:12.024213+00:00"
  }
}